-Handheld Veterinary Capnography Monitor
Handheld Veterinary Capnography Monitor
Product Overview & Clinic Significance of EtCO2 Monitoring
unimed VET Handheld Veterinary Capnography Monitor is portable handheld carbon dioxide monitoring equipment specially for animal anesthesia and respiratory monitoring.
Adaptation diseases: 1. Safe application for anesthetic machines and ventlators. 2. Insuficiency of all kinds of respiraton. 3. Cardio-pumonary resuscitation. 4. Serious shock. 5. Cardiac falure and infarct 6. Locating intubated catheter in general anesthetic trachea.
Core Product Features
Rechargeable Lithium Battery
3.6V,3800mAh lithium battery, 12 hours continuous working time, only 4 hours full charging time.
Ultra Compact Handheld Size
Dimension:70mm(W)x160mm(H)x40mm(D), light weight only 400 grams for portable carry.
Wide EtCO2 Measuring Range
EtCO2/CO2 range:0-150mmHg(0-20kPa,or 0-20%(VV)), multi standard unit optional display.
24 Hours Trend Data Storage
Supports 24 hours trend length for EtCO2 and respiration rate historical data review.
Customizable Update Interval
EtCO2 update: every breath, 10sec,20sec or 30sec selectable; flux 50-250cc/min adjustable.
Stable Working Environment
Working temperature:5-40°C, humidity 30-75%(non-condensing), atmospheric pressure 55-115kPa.
Application Scenarios
Veterinary Anesthesia Room
Real-time EtCO2 monitoring during animal general anesthesia surgery.
Emergency Animal Rescue
Respiratory monitoring for shock, heart failure and cardiopulmonary resuscitation.
Vet Clinic Ward
Long-term monitoring for animals with various respiratory insufficiency.
Veterinary Research Lab
Accurate carbon dioxide data recording for animal medical experiments.
Technical Specifications
| AC Power Input | 100V-250V, 50Hz/60 Hz |
|---|---|
| AC Power Consumption | 10W |
| Working Temperature | 5-40°C |
| Working Humidity | 30-75%( non-condensing) |
| Atmospheric Pressure Range | 55-115kPa |
| Battery Parameter | 3.6V,3800mAh lithium rechargeable battery |
| Battery Working Time | 12 hours (approximately) |
| Full Charging Time | 4 hours from empty to full |
| Dimension | 70mm(W)x160mm(H)x40mm(D) |
| Net Weight | 400 grams |
| EtCO2/CO2 Measuring Range | 0-150mmHg(0-20kPa,or 0-20%(VV)) |
| EtCO2 Accuracy Standard | +2mmHg when 0-40mmHg +5%(reading) when>41-70mmHg +8%(reading) when >71-100mmHg ±10%(reading) when>101-150mmHg |
| Respiration Rate Range | 3-150 t/min |
| Respiration Rate Accuracy | the bigger value of±1%(reading) or 1times/min |
| Flux Adjustable Range | 50-250cc/min selectable |
| Trend Storage Length | 24hours for EtCO2 & Respiration Rate |
| Notice | No futher notification if some technical specification change Please take update technical specification or test result as the stardand |