Referencias cruzadas de números de pieza de fabricantes de equipos originales: |
|
|
Fabricante |
N.º de pieza de OEM |
|
Biolight |
15-100-0004 |
|
Criticare |
CAT 1073/IS |
|
Compatibilidad: |
|
|
Fabricante |
Modelo |
|
AAMI |
Todos |
|
Abbott |
EX-50; Lifecare 5100; Lifecare 5200 |
|
Advanced Instrumentations |
PM-1000; PM-1000EX |
|
American Optical |
26125; 33167; 5260; 5330; Pulsar 4 |
|
ATL |
800; 800 Plus; 800Plus; Apogee; CX ATL Ultrasound; CX200; CX400; HDI 9/200; HDI 9/2000; Interspec Cardiology XL; Mark IV; Mark Vii; Ultramark 4/5/7/9 |
|
BCI |
3101; 3404; 6100; 6200; 9100; 9200; Advisor; Autocorr; Autocorr: Surgivet |
|
Carewell |
CPM-8000 |
|
CAS Med |
CAS740 VITAL SIGNS |
|
Conmed |
90347 |
|
Contec |
CMS9000; CMS6800; CMS 6800; CMS 8000; CMS 9000 |
|
Criticare |
1100; 2200; 504US; 504USP; 506; 507; 507E; 507ELC2; 507S; 508; 602-4B; 602-4USP; 8100; 8100E; 8100EP; Poet 2; Scholar; nCompass; nGenuity 8100E |
|
Datex Ohmeda |
enGuard CM5 |
|
Digicare |
LW600 |
|
DIN Style |
Todos |
|
Dixtal |
DX 2022; DX 2515 |
|
Draeger > Air Shields |
Porta-Fib I; Porta-Fib II; Porta-Fib III; HRRM-71-1; HRRM-71-2; System 5 (nuevo); System 6 (neonatal); II; III |
|
Draeger |
Vitalert 2000; Vitalert 3000 |
|
DRE |
Waveline EZ MAX |
|
Edan |
iM50, iM60, iM70, iM80, iM8, iM8A, iM9, iM9A, M3, M3A, M3B, M8, M8A, M8B, M9, M9A |
|
GE Healthcare > Corometrics |
556 |
|
GE Healthcare > Critikon > Dinamap |
8100T; Serie 8700; 8700/9700; Serie 9700; MPS Select; Pro 1000 |
|
Goldway |
UT4000A; UT4000Apro; UT4000B; UT4000C; UT4000F; UT4000Fpro; UT6000A; UT6000F; UT4800; G40; UT4000F Pro |
|
Guthan |
1000 |
|
Infinium |
Infitron II; Omni; Omni II |
|
Interspec (Irex) (JandJ) |
Cardiology XL; Mark IV; Mark Vii; Ultramark 4; Ultramark 4 Plus; Ultramark 5; Ultramark 7; Ultramark 9 |
|
Invivo |
360SL; 450SL; 521A; Escort 100; Escort 101; Escort 102; Escort 200; Escort 300; PortaPak 1000; PortaPak 80; PortaPak 90; Prism 101; Prism 102; Prism 200; Prism 300; Millennia 3500; 101; 102; 200; 300; PortaPak 90/1000; Prism |
|
Ivy Biomedical |
101 (antes de 1989); 402; 700; 7800; Cardiac Trigger Monitor 3150; 101; 101 (antes de 1989); 3000 |
|
LSI |
261; LS5 |
|
Mediana |
YM6000 |
|
Medtronic > Physio Control |
Lifepak 6; VSM-1ESF; 1440/R; Lifepak 10; Lifepak 5; Lifepak 6S; Lifepak 7; Lifepak 8; Lifepak 9; VSM-2; VSM-2ESF; VSM-3 |
|
Midmark > Cardell |
9403V; 9405; MAX-12 Duo HD; Max-1 |
|
Mindray |
DPM4; DPM5; MEC200; MEC1000; MEC1200; MEC2000; PM7000; PM8000; PM9000; PM9000EX |
|
Nellcor |
C-LOCK; N-1000; N-200; N-250; NPB-3900; NPB-4000 |
|
Nihon Kohden |
BSM-8301A; BSM-8302A; BSM-8500A; BSM-8502A; OEC-6102A; OEC-7102A; OEC-8108A; OEC-6105A; TEC-7100A; OEC-5200A; OEC-7200A; OEC-7300A; 7102A; BSM-7102A; BSM-7300A; BSM-8108A; BSM-8800A; Life Scope 12; Life Scope 6; Life Scope 7; Life Scope 8; Life Scope 9; MU-831RA; OEC-6102A (n.º de serie >20156); OEC-6105A (n.º de serie >20226); TEC 5531E; TEC-5200A (n.º de serie >20421); TEC-7200A; TEC-7300A |
|
Novametrix |
902; 903; 910; Life Defense 1 |
|
Omron > Colin |
CBM3000; BP-308; BP-408; M20; M30; MS20 |
|
PaceTech |
2100; 2200; 4000; 4100; MiniMax 4000CL; Minipack 300; Minipack 3000; Minipack 3000/3100; Minipack 3100; Modular/4100CL; Vitalmax 2100; Vitalmax 2200; Vitalmax 4000; Vitalmax 4000 Modular; Vitalmax 4000CL; Vitalmax 4100; Vitalmax 4100CL; Vitalmax 800 Plus |
|
Philips |
iE33 xMatrix Ultrasound CX50; M3921A A1; M3923A A1; M3925A A1; M3927A A3; M3929A A3 |
|
PPG |
Guardian 1001; N1001 |
|
Siemens |
Acuson C256; Acuson CV70; Acuson Sequoia 512; Acuson X300; Acuson X700; SC 2000; SC 3000; Sirecust 300DU; Sirecust 610; Sirecust 630; Sirecust DU |
|
Spacelabs |
Ultraview 90300; Ultraview 90400; Ultraview 90600; Ultraview 90700; Series500; 600Series; 900Series; 400; 500; 600; 67112; 900; 90300; 90303; 90303B; 90308; 90400; 90408; 90425; 90428; 90431; 90432; 90470; 90600; 90603A; 90700; 90701; 90721; 90724; AriaTele; Medic 3; Medic 4; Medic 5; Medic 6; PC Bedside; PCMS; Serie 500; Serie 600; Serie 900; TEK-208; TEK-208/408/511/512/514/521; TEK-408; TEK-413; TEK-414; TEK-511; TEK-512; TEK-514; TEK-5214045 |
|
Tektronix |
4045 Defib; Serie 208; Serie 400; Serie 500; Serie 4045 Defib/208/400/500 |
|
Welch Allyn |
Welch Allyn Propaq 100; Welch Allyn serie 200; Atlas Propaq Encore; Propaq CS; Ultra Smart; 1500; Atlas; Atlas serie 6200; PIC 30; PIC 40; PIC 50; Propaq serie 100; Propaq serie 200; Propaq 206 EMPSC; Propaq Encore |
|
ZOLL |
D900; Serie E; Serie M; PD1200; PD1400; PD1600; PD1700; PD2000; Serie R |
|
Especificaciones técnicas: |
|
|
Categoría |
Cable de ECG reutilizable de una pieza |
|
Conformidad reglamentaria |
CE, FDA, Anvisa, MDSAP, ANSI/AAMI EC53, serie ISO 10993 |
|
Conector del extremo del monitor |
Redondo de 6 pines, Negro |
|
Conector del extremo del paciente |
Extremo a presión |
|
Sin látex |
Sí |
|
Longitud total del cable |
3.4M |
|
Color del cable troncal |
Gris |
|
Longitud del cable troncal |
2.5m |
|
Material del cable troncal |
Cubierta de TPU |
|
Diámetro del cable troncal |
5.0mm |
|
Longitud del cable del electrodo |
0.9M |
|
Color del cable del electrodo |
Gris |
|
Material del cable del electrodo |
Cubierta de TPU |
|
Diámetro del cable del electrodo |
2.6mm |
|
Codificación por colores |
IEC |
|
Número de derivaciones |
3 derivaciones |
|
Tipo de embalaje |
Bolsa |
|
Unidad de embalaje |
1 |
|
Peso del paquete |
195g |
|
Garantía |
6 meses |